All the conveniences of modern living - heat, central air, refrigeration, communication - are nothing without power. When the power supply is disrupted, our lives and businesses can come to a sudden halt. An automatic standby generator protects you from power failures, restoring power within seconds of an outage, so you can have peace of mind and the power you need.
Generac’s new Protector® Series diesel generators raise the bar for residential and light commercial diesel generators. Building and zoning codes can vary wildly from one region to another. In the past, the only answer was to order expensive, custom-configured solutions. Until now.
Generac’s diesel-powered Protector Series features Code Ready, a set of popular preconfigured options and a range of code-driven accessories, so you can feel confident that your generator will be able to conform to the required local codes. The Protector Series is versatile, adaptable, meets UL requirements, and is an affordable optional standby diesel generator for your backup power needs.
Features
- Evolution™ Controller: The next generation of intuitive controllers featuring a multilingual, two-line LCD text display with color-coded, backlit buttons.
- Quiet-Test™ mode: All standby generators run a weekly test to ensure the system is running properly. Thanks to Quiet-Test, your Protector Series standby generator runs its self-test at a lower, quieter RPM than standard operation.
- Mobile Link™ Connectivity: Comes standard with all Protector Series generators. Mobile Link allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet or PC. Easily access information, such as the current operating status and the generator’s maintenance schedule. Connect your account to an authorized service dealer for fast, friendly and convenient assistance. With Mobile Link, your generator is taken care of before the next outage.
- 5 Year Limited Warranty: We are proud of our innovative product design, high quality and first-class reliability so we stand behind them with a strong 5-year limited warranty.
- Code Ready: The Protector Series offers compatibility with a variety of environments, with external vent and fill, a UL/CUL 142-listed, double-walled base tank, a UL/CUL 2200-listed generator, and a wide range of code-driven accessories.
- NEW! Extended tank option. Full load runtime of 2+ days!
- Ease of installation and service: External viewing window for easy inspection of generator status and breaker position. Removable doors for easy service and fuel fill access
- Isochronous Governor – electronic governor control for tight and precise load response and voltage (+/- 1%) and frequency regulation.
- Available in single- and three-phase configurations.
Generator Specifications
- Type: Synchronous
- Rotor Insulation Class: H
- Stator Insulation Class: H
- Telephone Interference Factor (TIF): <50
- Alternator Output Leads 1-Phase: 3 wire
- Alternator Output Leads 3-Phase: 6 wire
- Bearings: Single Sealed Cartridge
- Coupling: Direct, Flexible Disc
- Excitation System: Direct
- Total Harmonic Distortion: <5%
Voltage Regulation
- Type: Electronic
- Sensing: Single-phase
- Regulation: ±1%
- Features: Adjustable voltage & gain
Governor Specifications
- Type: Electronic isochronous
- Steady State Regulation: ± 0.25%
Electrical System
- Battery Charger Alternator: 50 Amp
- Static Battery Charger: 2 Amp
- Recommended Battery (battery included): Group 31, 925 CCA
- System Voltage: 12 Volts
Alternator Specifications
- Revolving field heavy duty generator
- Directly connected to the engine
- Operating temperature rise 120 °C above a 40 °C ambient
- Class H insulation is NEMA rated
- Class F insulation is NEMA rated
- All models fully prototype tested
Enclosure Features
- Aluminum weather protective enclosure: Provides protection against mother nature. Electrostatically applied textured epoxy paint for added durability.
- Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampening.
- Small, compact, attractive: Makes for an easy, eye appealing installation.
- SAE: Sound attenuated enclosure ensures quiet operation.
Engine Specifications
- Make: Mitsubishi
- Type: In-line
- Cylinders: 4
- Displacement: 2.5
- Bore: 3.46/88
- Stroke: 4.06/103
- Compression Ratio: 22:1
- Intake Air System: Naturally aspirated
- Cylinder Head Type: Cast iron OHV
- Piston Type: Aluminum
Engine Lubrication System
- Oil Pump Type: Gear
- Oil Filter Type: Full Flow Spin-On Canister
- Crankcase Capacity: 6.87 qt (6.5 L)
Engine Cooling System
- Water Pump: Pre-lubed, self-sealing
- Fan Speed: 2,376 RPM
- Fan Diameter: 18.11 in. (460 cm)
- Fan Mode: Pusher
Fuel System
- Fuel Type: Ultra low sulfur diesel fuel
- Fuel Pump Type: Mechanical engine driven gear
- injector Type: Mechanical
- Fuel Supply Line: 0.31 in. (7.94 mm) (ID)
- Fuel Specification: ASTM
- Fuel Filtering (microns): 6
Weights and Dimensions
- Tank size: 32 gal. or 95 gal.
- Weight: 32 - 1,528 lb. (693 kg); 95 - 1,757 lb. (797 kg)
- Dimensions (LxWXH): 32 - 81 x 31 x 51 in. (206 x 79 x 129 cm); 95 - 81 x 31 x 61 in. (206 x 79 x 165 cm)
Tank Specifications
- Total Capacity: 32 Tank - 33.5 gal. (127 L); 32 Tank - 98.5 gal. (372.9 L)
- Usable Capacity: 32 Tank - 32 gal. (121 L); 32 Tank - 95 ga. (359.6 L)
- Run Time at 1/2 Load (hrs): 32 Tank - 31 hrs; 32 Tank - 92.2 hrs
Generator Output Voltage/Kw - 60 Hz
- 120 / 240 V, 10, 1.0 pf: kW LPG: 20; Amp LPG: 83; kW Nat. Gas: 16; Amp Nat. Gas: 67; CB Size (Both): 100
- 120 / 208 V, 30, 0.8 pf: kW LPG: 20; Amp LPG: 69; kW Nat. Gas: 16; Amp Nat. Gas: 56; CB Size (Both): 80
- 120 / 240 V, 30, 0.8 pf: kW LPG: 20; Amp LPG: 60; kW Nat. Gas: 16; Amp Nat. Gas: 48; CB Size (Both): 70
Surge Capacity in Amps
- 120/240 V, 10: (15%) 87; (30%) 211
- 120/208 V, 30: (15%) 59; (30%) 143
- 120/240 V, 30: (15%) 51; (30%) 124
Engine Fuel Consumption
- 25% of rated load: 0.77 gal/hr; 2.9 l/hr
- 50% of rated load: 1.03 gal/hr; 3.90 l/hr
- 75% of rated load: 1.46 gal/hr; 45.53 l/hr
- 100% of rated load: 1.97 gal/hr; 7.46 l/hr
Engine Cooling
- Air flow (inlet air including alternator and combustion air): 2,750 cfm (78 cmm)
- System coolant capacity: 3.0 gal. (11.4 L)
- Heat rejection to coolant: 95,220 BTU per hr (100.5 MJ per hr)
- Maximum operation air temperature on radiator: 122° F (50° C)
- Maximum ambient temperature: 122° F (50° C)
Combustion Requirements
- Flow at Rated Power scfm: 86.3 cfm (2.4 cmm)
Sound Emissions
- Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* : 65
- Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load*: 70
Exhaust
- Exhaust Flow at Rated Output scfm: 98.88 m3 (2.8 min)
- Exhaust Temperature (Rated Output): 900° F (482° C)
Engine Parameters
- Rated Synchronous: 1,800 RPM
- HP at rated KW: 33.5 HP
Power Adjustment for Ambient Conditions
- Temperature Deration: 3% for every 5 °C above 25 °C or 1.7% for every 5 °F above 77 °F
- Altitude Deration: 1% for every 100 m above 305 m or 3% for every 1,000 ft above 1,000 ft.
Controller Features
- 2-Line Plain Text Multilingual LCD Display: Simple user interface for ease of operation.
- Mode Buttons: Auto - Automatic Start on Utility failure. Programmable 7 day exerciser.; Manual - Start with starter control, unit stays on. If utility fails, transfer to load takes place.; Off - Stops unit. Power is removed. Control and charger still operate.
- Ready to Run/Maintenance Message: Standard
- Engine Run Hours Indication: Standard
- Programmable Start Delay Between 2-1,500 Seconds: Standard (programmable by dealer only)
- Utility Voltage Loss / Return to Utility Adjustable: From 140-171 V/190-216 V
- Future Set Capable Exerciser / Exercise Set Error Warning: Standard
- Run / Alarm/Maintenance Logs: 50 Events Each
- Engine Start Sequence: Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
- Starter Lock-out: Starter cannot re-engage until 5 seconds after engine has stopped.
- Smart Battery Charger: Standard
- Charger Fault/Missing AC Warning: Standard
- Low Battery / Battery Problem Protection and Battery Condition Indication: Standard
- Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
- Under-Frequency / Overload/Stepper Overcurrent Protection: Standard
- Safety Fused/Fuse Problem Protection: Standard
- Automatic Low Oil Pressure: Standard
- Overcrank / Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown: Standard
- High Engine Temperature Shutdown: Standard
- Internal Fault/Incorrect Wiring Protection: Standard
- Common External Fault Capability: Standard
- Field Upgradeable Firmware: Standard
- Low Coolant Level Shutdown: Standard
Remote Monitoring
- Ability to view generator status: Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind.
- Ability to view generator Exercise/Run and Total Hours: Review the generator's complete protection profile for exercise hours and total hours.
- Ability to view generator maintenance information: Provides maintenance information for the specific model generator when scheduled maintenance is due.
- Monthly report with previous month's activity: Detailed monthly reports provide historical generator information.
- Ability to view generator battery information: Built in battery diagnostics displaying current state of the battery.
- Weather information: Provides detailed local ambient weather conditions for generator location.